1 * Broadcom BCM7xxx Ethernet Systemport Controller (SYSTEMPORT)
4 - compatible: should be one of "brcm,systemport-v1.00" or "brcm,systemport"
5 - reg: address and length of the register set for the device.
6 - interrupts: interrupts for the device, first cell must be for the the rx
7 interrupts, and the second cell should be for the transmit queues
8 - local-mac-address: Ethernet MAC address (48 bits) of this adapter
9 - phy-mode: Should be a string describing the PHY interface to the
10 Ethernet switch/PHY, see Documentation/devicetree/bindings/net/ethernet.txt
11 - fixed-link: see Documentation/devicetree/bindings/net/fixed-link.txt for
12 the property specific details
15 - systemport,num-tier2-arb: number of tier 2 arbiters, an integer
16 - systemport,num-tier1-arb: number of tier 1 arbiters, an integer
17 - systemport,num-txq: number of HW transmit queues, an integer
18 - systemport,num-rxq: number of HW receive queues, an integer
22 compatible = "brcm,systemport-v1.00";
23 reg = <0xf04a0000 0x4650>;
24 local-mac-address = [ 00 11 22 33 44 55 ];
25 fixed-link = <0 1 1000 0 0>;
27 interrupts = <0x0 0x16 0x0>,