OSDN Git Service

Merge branch 'kconfig' of git://git.kernel.org/pub/scm/linux/kernel/git/mmarek/kbuild
[uclinux-h8/linux.git] / drivers / md / Kconfig
1 #
2 # Block device driver configuration
3 #
4
5 menuconfig MD
6         bool "Multiple devices driver support (RAID and LVM)"
7         depends on BLOCK
8         select SRCU
9         help
10           Support multiple physical spindles through a single logical device.
11           Required for RAID and logical volume management.
12
13 if MD
14
15 config BLK_DEV_MD
16         tristate "RAID support"
17         ---help---
18           This driver lets you combine several hard disk partitions into one
19           logical block device. This can be used to simply append one
20           partition to another one or to combine several redundant hard disks
21           into a RAID1/4/5 device so as to provide protection against hard
22           disk failures. This is called "Software RAID" since the combining of
23           the partitions is done by the kernel. "Hardware RAID" means that the
24           combining is done by a dedicated controller; if you have such a
25           controller, you do not need to say Y here.
26
27           More information about Software RAID on Linux is contained in the
28           Software RAID mini-HOWTO, available from
29           <http://www.tldp.org/docs.html#howto>. There you will also learn
30           where to get the supporting user space utilities raidtools.
31
32           If unsure, say N.
33
34 config MD_AUTODETECT
35         bool "Autodetect RAID arrays during kernel boot"
36         depends on BLK_DEV_MD=y
37         default y
38         ---help---
39           If you say Y here, then the kernel will try to autodetect raid
40           arrays as part of its boot process. 
41
42           If you don't use raid and say Y, this autodetection can cause 
43           a several-second delay in the boot time due to various
44           synchronisation steps that are part of this step.
45
46           If unsure, say Y.
47
48 config MD_LINEAR
49         tristate "Linear (append) mode"
50         depends on BLK_DEV_MD
51         ---help---
52           If you say Y here, then your multiple devices driver will be able to
53           use the so-called linear mode, i.e. it will combine the hard disk
54           partitions by simply appending one to the other.
55
56           To compile this as a module, choose M here: the module
57           will be called linear.
58
59           If unsure, say Y.
60
61 config MD_RAID0
62         tristate "RAID-0 (striping) mode"
63         depends on BLK_DEV_MD
64         ---help---
65           If you say Y here, then your multiple devices driver will be able to
66           use the so-called raid0 mode, i.e. it will combine the hard disk
67           partitions into one logical device in such a fashion as to fill them
68           up evenly, one chunk here and one chunk there. This will increase
69           the throughput rate if the partitions reside on distinct disks.
70
71           Information about Software RAID on Linux is contained in the
72           Software-RAID mini-HOWTO, available from
73           <http://www.tldp.org/docs.html#howto>. There you will also
74           learn where to get the supporting user space utilities raidtools.
75
76           To compile this as a module, choose M here: the module
77           will be called raid0.
78
79           If unsure, say Y.
80
81 config MD_RAID1
82         tristate "RAID-1 (mirroring) mode"
83         depends on BLK_DEV_MD
84         ---help---
85           A RAID-1 set consists of several disk drives which are exact copies
86           of each other.  In the event of a mirror failure, the RAID driver
87           will continue to use the operational mirrors in the set, providing
88           an error free MD (multiple device) to the higher levels of the
89           kernel.  In a set with N drives, the available space is the capacity
90           of a single drive, and the set protects against a failure of (N - 1)
91           drives.
92
93           Information about Software RAID on Linux is contained in the
94           Software-RAID mini-HOWTO, available from
95           <http://www.tldp.org/docs.html#howto>.  There you will also
96           learn where to get the supporting user space utilities raidtools.
97
98           If you want to use such a RAID-1 set, say Y.  To compile this code
99           as a module, choose M here: the module will be called raid1.
100
101           If unsure, say Y.
102
103 config MD_RAID10
104         tristate "RAID-10 (mirrored striping) mode"
105         depends on BLK_DEV_MD
106         ---help---
107           RAID-10 provides a combination of striping (RAID-0) and
108           mirroring (RAID-1) with easier configuration and more flexible
109           layout.
110           Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
111           be the same size (or at least, only as much as the smallest device
112           will be used).
113           RAID-10 provides a variety of layouts that provide different levels
114           of redundancy and performance.
115
116           RAID-10 requires mdadm-1.7.0 or later, available at:
117
118           ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
119
120           If unsure, say Y.
121
122 config MD_RAID456
123         tristate "RAID-4/RAID-5/RAID-6 mode"
124         depends on BLK_DEV_MD
125         select RAID6_PQ
126         select ASYNC_MEMCPY
127         select ASYNC_XOR
128         select ASYNC_PQ
129         select ASYNC_RAID6_RECOV
130         ---help---
131           A RAID-5 set of N drives with a capacity of C MB per drive provides
132           the capacity of C * (N - 1) MB, and protects against a failure
133           of a single drive. For a given sector (row) number, (N - 1) drives
134           contain data sectors, and one drive contains the parity protection.
135           For a RAID-4 set, the parity blocks are present on a single drive,
136           while a RAID-5 set distributes the parity across the drives in one
137           of the available parity distribution methods.
138
139           A RAID-6 set of N drives with a capacity of C MB per drive
140           provides the capacity of C * (N - 2) MB, and protects
141           against a failure of any two drives. For a given sector
142           (row) number, (N - 2) drives contain data sectors, and two
143           drives contains two independent redundancy syndromes.  Like
144           RAID-5, RAID-6 distributes the syndromes across the drives
145           in one of the available parity distribution methods.
146
147           Information about Software RAID on Linux is contained in the
148           Software-RAID mini-HOWTO, available from
149           <http://www.tldp.org/docs.html#howto>. There you will also
150           learn where to get the supporting user space utilities raidtools.
151
152           If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y.  To
153           compile this code as a module, choose M here: the module
154           will be called raid456.
155
156           If unsure, say Y.
157
158 config MD_MULTIPATH
159         tristate "Multipath I/O support"
160         depends on BLK_DEV_MD
161         help
162           MD_MULTIPATH provides a simple multi-path personality for use
163           the MD framework.  It is not under active development.  New
164           projects should consider using DM_MULTIPATH which has more
165           features and more testing.
166
167           If unsure, say N.
168
169 config MD_FAULTY
170         tristate "Faulty test module for MD"
171         depends on BLK_DEV_MD
172         help
173           The "faulty" module allows for a block device that occasionally returns
174           read or write errors.  It is useful for testing.
175
176           In unsure, say N.
177
178 source "drivers/md/bcache/Kconfig"
179
180 config BLK_DEV_DM_BUILTIN
181         bool
182
183 config BLK_DEV_DM
184         tristate "Device mapper support"
185         select BLK_DEV_DM_BUILTIN
186         ---help---
187           Device-mapper is a low level volume manager.  It works by allowing
188           people to specify mappings for ranges of logical sectors.  Various
189           mapping types are available, in addition people may write their own
190           modules containing custom mappings if they wish.
191
192           Higher level volume managers such as LVM2 use this driver.
193
194           To compile this as a module, choose M here: the module will be
195           called dm-mod.
196
197           If unsure, say N.
198
199 config DM_DEBUG
200         bool "Device mapper debugging support"
201         depends on BLK_DEV_DM
202         ---help---
203           Enable this for messages that may help debug device-mapper problems.
204
205           If unsure, say N.
206
207 config DM_BUFIO
208        tristate
209        depends on BLK_DEV_DM
210        ---help---
211          This interface allows you to do buffered I/O on a device and acts
212          as a cache, holding recently-read blocks in memory and performing
213          delayed writes.
214
215 config DM_BIO_PRISON
216        tristate
217        depends on BLK_DEV_DM
218        ---help---
219          Some bio locking schemes used by other device-mapper targets
220          including thin provisioning.
221
222 source "drivers/md/persistent-data/Kconfig"
223
224 config DM_CRYPT
225         tristate "Crypt target support"
226         depends on BLK_DEV_DM
227         select CRYPTO
228         select CRYPTO_CBC
229         ---help---
230           This device-mapper target allows you to create a device that
231           transparently encrypts the data on it. You'll need to activate
232           the ciphers you're going to use in the cryptoapi configuration.
233
234           For further information on dm-crypt and userspace tools see:
235           <http://code.google.com/p/cryptsetup/wiki/DMCrypt>
236
237           To compile this code as a module, choose M here: the module will
238           be called dm-crypt.
239
240           If unsure, say N.
241
242 config DM_SNAPSHOT
243        tristate "Snapshot target"
244        depends on BLK_DEV_DM
245        select DM_BUFIO
246        ---help---
247          Allow volume managers to take writable snapshots of a device.
248
249 config DM_THIN_PROVISIONING
250        tristate "Thin provisioning target"
251        depends on BLK_DEV_DM
252        select DM_PERSISTENT_DATA
253        select DM_BIO_PRISON
254        ---help---
255          Provides thin provisioning and snapshots that share a data store.
256
257 config DM_CACHE
258        tristate "Cache target (EXPERIMENTAL)"
259        depends on BLK_DEV_DM
260        default n
261        select DM_PERSISTENT_DATA
262        select DM_BIO_PRISON
263        ---help---
264          dm-cache attempts to improve performance of a block device by
265          moving frequently used data to a smaller, higher performance
266          device.  Different 'policy' plugins can be used to change the
267          algorithms used to select which blocks are promoted, demoted,
268          cleaned etc.  It supports writeback and writethrough modes.
269
270 config DM_CACHE_MQ
271        tristate "MQ Cache Policy (EXPERIMENTAL)"
272        depends on DM_CACHE
273        default y
274        ---help---
275          A cache policy that uses a multiqueue ordered by recent hit
276          count to select which blocks should be promoted and demoted.
277          This is meant to be a general purpose policy.  It prioritises
278          reads over writes.
279
280 config DM_CACHE_CLEANER
281        tristate "Cleaner Cache Policy (EXPERIMENTAL)"
282        depends on DM_CACHE
283        default y
284        ---help---
285          A simple cache policy that writes back all data to the
286          origin.  Used when decommissioning a dm-cache.
287
288 config DM_ERA
289        tristate "Era target (EXPERIMENTAL)"
290        depends on BLK_DEV_DM
291        default n
292        select DM_PERSISTENT_DATA
293        select DM_BIO_PRISON
294        ---help---
295          dm-era tracks which parts of a block device are written to
296          over time.  Useful for maintaining cache coherency when using
297          vendor snapshots.
298
299 config DM_MIRROR
300        tristate "Mirror target"
301        depends on BLK_DEV_DM
302        ---help---
303          Allow volume managers to mirror logical volumes, also
304          needed for live data migration tools such as 'pvmove'.
305
306 config DM_LOG_USERSPACE
307         tristate "Mirror userspace logging"
308         depends on DM_MIRROR && NET
309         select CONNECTOR
310         ---help---
311           The userspace logging module provides a mechanism for
312           relaying the dm-dirty-log API to userspace.  Log designs
313           which are more suited to userspace implementation (e.g.
314           shared storage logs) or experimental logs can be implemented
315           by leveraging this framework.
316
317 config DM_RAID
318        tristate "RAID 1/4/5/6/10 target"
319        depends on BLK_DEV_DM
320        select MD_RAID1
321        select MD_RAID10
322        select MD_RAID456
323        select BLK_DEV_MD
324        ---help---
325          A dm target that supports RAID1, RAID10, RAID4, RAID5 and RAID6 mappings
326
327          A RAID-5 set of N drives with a capacity of C MB per drive provides
328          the capacity of C * (N - 1) MB, and protects against a failure
329          of a single drive. For a given sector (row) number, (N - 1) drives
330          contain data sectors, and one drive contains the parity protection.
331          For a RAID-4 set, the parity blocks are present on a single drive,
332          while a RAID-5 set distributes the parity across the drives in one
333          of the available parity distribution methods.
334
335          A RAID-6 set of N drives with a capacity of C MB per drive
336          provides the capacity of C * (N - 2) MB, and protects
337          against a failure of any two drives. For a given sector
338          (row) number, (N - 2) drives contain data sectors, and two
339          drives contains two independent redundancy syndromes.  Like
340          RAID-5, RAID-6 distributes the syndromes across the drives
341          in one of the available parity distribution methods.
342
343 config DM_ZERO
344         tristate "Zero target"
345         depends on BLK_DEV_DM
346         ---help---
347           A target that discards writes, and returns all zeroes for
348           reads.  Useful in some recovery situations.
349
350 config DM_MULTIPATH
351         tristate "Multipath target"
352         depends on BLK_DEV_DM
353         # nasty syntax but means make DM_MULTIPATH independent
354         # of SCSI_DH if the latter isn't defined but if
355         # it is, DM_MULTIPATH must depend on it.  We get a build
356         # error if SCSI_DH=m and DM_MULTIPATH=y
357         depends on SCSI_DH || !SCSI_DH
358         ---help---
359           Allow volume managers to support multipath hardware.
360
361 config DM_MULTIPATH_QL
362         tristate "I/O Path Selector based on the number of in-flight I/Os"
363         depends on DM_MULTIPATH
364         ---help---
365           This path selector is a dynamic load balancer which selects
366           the path with the least number of in-flight I/Os.
367
368           If unsure, say N.
369
370 config DM_MULTIPATH_ST
371         tristate "I/O Path Selector based on the service time"
372         depends on DM_MULTIPATH
373         ---help---
374           This path selector is a dynamic load balancer which selects
375           the path expected to complete the incoming I/O in the shortest
376           time.
377
378           If unsure, say N.
379
380 config DM_DELAY
381         tristate "I/O delaying target"
382         depends on BLK_DEV_DM
383         ---help---
384         A target that delays reads and/or writes and can send
385         them to different devices.  Useful for testing.
386
387         If unsure, say N.
388
389 config DM_UEVENT
390         bool "DM uevents"
391         depends on BLK_DEV_DM
392         ---help---
393         Generate udev events for DM events.
394
395 config DM_FLAKEY
396        tristate "Flakey target"
397        depends on BLK_DEV_DM
398        ---help---
399          A target that intermittently fails I/O for debugging purposes.
400
401 config DM_VERITY
402         tristate "Verity target support"
403         depends on BLK_DEV_DM
404         select CRYPTO
405         select CRYPTO_HASH
406         select DM_BUFIO
407         ---help---
408           This device-mapper target creates a read-only device that
409           transparently validates the data on one underlying device against
410           a pre-generated tree of cryptographic checksums stored on a second
411           device.
412
413           You'll need to activate the digests you're going to use in the
414           cryptoapi configuration.
415
416           To compile this code as a module, choose M here: the module will
417           be called dm-verity.
418
419           If unsure, say N.
420
421 config DM_SWITCH
422         tristate "Switch target support (EXPERIMENTAL)"
423         depends on BLK_DEV_DM
424         ---help---
425           This device-mapper target creates a device that supports an arbitrary
426           mapping of fixed-size regions of I/O across a fixed set of paths.
427           The path used for any specific region can be switched dynamically
428           by sending the target a message.
429
430           To compile this code as a module, choose M here: the module will
431           be called dm-switch.
432
433           If unsure, say N.
434
435 endif # MD