thermal/drivers/hisi: Simplify the temperature/step computation
authorDaniel Lezcano <daniel.lezcano@linaro.org>
Thu, 19 Oct 2017 17:05:46 +0000 (19:05 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Mon, 25 Dec 2017 13:23:46 +0000 (14:23 +0100)
commit1b2c46a6be45a36c64230cc23859e2113ab1cc49
treef8c6143714faf21541ba6d59ea800f491082535c
parent2dac559df962c064d13a14610e81535c55fcf33d
thermal/drivers/hisi: Simplify the temperature/step computation

commit 48880b979cdc9ef5a70af020f42b8ba1e51dbd34 upstream.

The step and the base temperature are fixed values, we can simplify the
computation by converting the base temperature to milli celsius and use a
pre-computed step value. That saves us a lot of mult + div for nothing at
runtime.

Take also the opportunity to change the function names to be consistent with
the rest of the code.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Reviewed-by: Leo Yan <leo.yan@linaro.org>
Tested-by: Leo Yan <leo.yan@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Kevin Wangtao <kevin.wangtao@hisilicon.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/thermal/hisi_thermal.c