staging: comedi: dt282x: prevent "empty acquisition" async commands
authorH Hartley Sweeten <hsweeten@visionengravers.com>
Tue, 9 Sep 2014 23:15:48 +0000 (16:15 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 11 Sep 2014 21:35:20 +0000 (14:35 -0700)
commit759658ddff327675bbf35063e2b04e0d7424124d
treefb6c0e11bc14b30149fc553fde351ebf4989b0e2
parent1a021d6387337c828c6e15c7fc65f3e013163f89
staging: comedi: dt282x: prevent "empty acquisition" async commands

This driver currently allows a cmd->stop_src == TRIG_COUNT with a cmd->stop_arg
of 0 for both the analog input and output async commands. The (*do_cmd) for
both subdevices sets up and starts the command without handling the "empty
acquisition". This results in the interrupt functions trying to transfer 0 data
samples.

Validate that the cmd->stop_arg is >= 1 in the (*do_cmdtest) to prevent the
"empty acquisition".

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>