OSDN Git Service

net: dsa: targeted MTU notifiers should only match on one port
authorVladimir Oltean <vladimir.oltean@nxp.com>
Mon, 21 Jun 2021 16:42:18 +0000 (19:42 +0300)
committerDavid S. Miller <davem@davemloft.net>
Mon, 21 Jun 2021 19:50:20 +0000 (12:50 -0700)
commit88faba20e2100c1f367133af56612742ad37df08
tree54b39a59d69c8c7294bf675f0e91520f27fce15d
parent4e4ab7950044d195f6e3d4dac328f506badb6efa
net: dsa: targeted MTU notifiers should only match on one port

dsa_slave_change_mtu() calls dsa_port_mtu_change() twice:
- it sends a cross-chip notifier with the MTU of the CPU port which is
  used to update the DSA links.
- it sends one targeted MTU notifier which is supposed to only match the
  user port on which we are changing the MTU. The "propagate_upstream"
  variable is used here to bypass the cross-chip notifier system from
  switch.c

But due to a mistake, the second, targeted notifier matches not only on
the user port, but also on the DSA link which is a member of the same
switch, if that exists.

And because the DSA links of the entire dst were programmed in a
previous round to the largest_mtu via a "propagate_upstream == true"
notification, then the dsa_port_mtu_change(propagate_upstream == false)
call that is immediately upcoming will break the MTU on the one DSA link
which is chip-wise local to the dp whose MTU is changing right now.

Example given this daisy chain topology:

   sw0p0     sw0p1     sw0p2     sw0p3     sw0p4
[  cpu  ] [  user ] [  user ] [  dsa  ] [  user ]
[   x   ] [       ] [       ] [   x   ] [       ]
                                  |
                                  +---------+
                                            |
   sw1p0     sw1p1     sw1p2     sw1p3     sw1p4
[  user ] [  user ] [  user ] [  dsa  ] [  dsa  ]
[       ] [       ] [       ] [       ] [   x   ]

ip link set sw0p1 mtu 9000
ip link set sw1p1 mtu 9000 # at this stage, sw0p1 and sw1p1 can talk
                           # to one another using jumbo frames
ip link set sw0p2 mtu 1500 # this programs the sw0p3 DSA link first to
                           # the largest_mtu of 9000, then reprograms it to
                           # 1500 with the "propagate_upstream == false"
                           # notifier, breaking communication between
                           # sw0p1 and sw1p1

To escape from this situation, make the targeted match really match on a
single port - the user port, and rename the "propagate_upstream"
variable to "targeted_match" to clarify the intention and avoid future
issues.

Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
net/dsa/dsa_priv.h
net/dsa/port.c
net/dsa/slave.c
net/dsa/switch.c