Add support for CCS811 VOC sensor. This patch adds support
for reading current and voltage across the sensor and TVOC
and equivalent CO2 values.

Scale and offset values have been computed according to datasheet:
    - For current: raw value is in microamps
        => 0.001 scale to convert to milliamps
    - For voltage: 1.65V = 1023, therefore 1650mV = 1023
        => 1650.0/1023 = 1.612903 scale to convert to millivolts
    - For eCO2: raw value range is from 400ppm to 8192ppm.
        => (val - 400) * (100 - 0) / (8192 - 400) + 0 =
           (val - 400) * 0.01283367 => offset: -400, scale = 0.012834
           to get a percentage value
    -For TVOC: raw value range is from 0ppb to 1187ppb.
        => (val - 0) * 100 / (1187 - 0) + 0 = val * 0.0842459 =>
            scale = 0.084246 for getting a percentage value