OSDN Git Service

iio: adc: at91: fix wrong channel number in triggered buffer mode
authorEugen Hristev <eugen.hristev@microchip.com>
Mon, 24 Sep 2018 07:51:44 +0000 (10:51 +0300)
committerJonathan Cameron <Jonathan.Cameron@huawei.com>
Sat, 29 Sep 2018 11:30:24 +0000 (12:30 +0100)
commitaea835f2dc8a682942b859179c49ad1841a6c8b9
treeedc3e2bb8c0e240cc4a61ffe669ae8fd9034eca0
parentbc1b45326223e7e890053cf6266357adfa61942d
iio: adc: at91: fix wrong channel number in triggered buffer mode

When channels are registered, the hardware channel number is not the
actual iio channel number.
This is because the driver is probed with a certain number of accessible
channels. Some pins are routed and some not, depending on the description of
the board in the DT.
Because of that, channels 0,1,2,3 can correspond to hardware channels
2,3,4,5 for example.
In the buffered triggered case, we need to do the translation accordingly.
Fixed the channel number to stop reading the wrong channel.

Fixes: 0e589d5fb ("ARM: AT91: IIO: Add AT91 ADC driver.")
Cc: Maxime Ripard <maxime.ripard@bootlin.com>
Signed-off-by: Eugen Hristev <eugen.hristev@microchip.com>
Acked-by: Ludovic Desroches <ludovic.desroches@microchip.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
drivers/iio/adc/at91_adc.c