thermal/drivers/tsens: Add timeout to get_temp_tsens_valid

The function can loop and lock the system if for whatever reason the bit
for the target sensor is NEVER valid. This is the case if a sensor is
disabled by the factory and the valid bit is never reported as actually
valid. Add a timeout check and exit if a timeout occurs. As this is
a very rare condition, handle the timeout only if the first read fails.
While at it also rework the function to improve readability and convert
to poll_timeout generic macro.

Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
Reviewed-by: Bjorn Andersson <bjorn.andersson@linaro.org>
Link: https://lore.kernel.org/r/20211007172859.583-1-ansuelsmth@gmail.com
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
drivers/thermal/qcom/tsens.c