OSDN Git Service

hwmon: (vt1211) Use request_muxed_region for Super-IO accesses
authorGuenter Roeck <linux@roeck-us.net>
Fri, 5 Apr 2019 15:53:08 +0000 (08:53 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Tue, 11 Jun 2019 10:23:59 +0000 (12:23 +0200)
commite3e58378c678bf12b1aa5be1e141aba29b9e2e58
tree9c2aff76b137504254ea578a1b45eedced5fca9c
parent488920af3bb37153c5f446c969a3e578d1484b18
hwmon: (vt1211) Use request_muxed_region for Super-IO accesses

[ Upstream commit 14b97ba5c20056102b3dd22696bf17b057e60976 ]

Super-IO accesses may fail on a system with no or unmapped LPC bus.

Also, other drivers may attempt to access the LPC bus at the same time,
resulting in undefined behavior.

Use request_muxed_region() to ensure that IO access on the requested
address space is supported, and to ensure that access by multiple drivers
is synchronized.

Fixes: 2219cd81a6cd ("hwmon/vt1211: Add probing of alternate config index port")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/hwmon/vt1211.c