OSDN Git Service

Attached is a patch to add bytea support to JDBC.
authorBruce Momjian <bruce@momjian.us>
Mon, 10 Sep 2001 15:07:05 +0000 (15:07 +0000)
committerBruce Momjian <bruce@momjian.us>
Mon, 10 Sep 2001 15:07:05 +0000 (15:07 +0000)
commitec0ad6740396f53fff240ce1153315f622a556e4
tree9fdb50c15f435927b2e73338901b0f57838188ac
parent6b50f9af333a2795b82dd3331df55c7e703f1bea
Attached is a patch to add bytea support to JDBC.

This patch does the following:

- Adds binary datatype support (bytea)
- Changes getXXXStream()/setXXXStream() methods to be spec compliant
- Adds ability to revert to old behavior

Details:

Adds support for the binary type bytea.  The ResultSet.getBytes() and
PreparedStatement.setBytes() methods now work against columns of bytea
type.  This is a change in behavior from the previous code which assumed
the column type was OID and thus a LargeObject.  The new behavior is
more complient with the JDBC spec as BLOB/CLOB are to be used for
LargeObjects and the getBytes()/setBytes() methods are for the databases
binary datatype (which is bytea in postgres).

Changes the behavior of the getBinaryStream(), getAsciiStream(),
getCharacterStream(), getUnicodeStream() and their setXXXStream()
counterparts.  These methos now work against either the bytea type
(BinaryStream) or the text types (AsciiStream, CharacterStream,
UnicodeStream).  The previous behavior was that these all assumed the
underlying column was of type OID and thus a LargeObject.  The
spec/javadoc for these methods indicate that they are for LONGVARCHAR
and LONGVARBINARY datatypes, which are distinct from the BLOB/CLOB
datatypes.  Given that the bytea and text types support upto 1G, they
are the LONGVARBINARY and LONGVARCHAR datatypes in postgres.

Added support for turning off the above new functionality.  Given that
the changes above are not backwardly compatible (however they are more
spec complient), I added the ability to revert back to the old behavior.
  The Connection now takes an optional parameter named 'compatible'.  If
the value of '7.1' is passed, the driver reverts to the 7.1 behavior.
If the parameter is not passed or the value '7.2' is passed the behavior
is the new behavior.  The mechanism put in place can be used in the
future when/if similar needs arise to change behavior.  This is
patterned after how Oracle does this (i.e. Oracle has a 'compatible'
parameter that behaves in a similar manner).

Misc fixes.  Cleaned up a few things I encountered along the way.

Note that in testing the patch I needed to ignore whitespace differences
in order to get it to apply cleanly (i.e. patch -l -i byteapatch.diff).
Also this patch introduces a new file
(src/interfaces/jdbc/org/postgresql/util/PGbytea.java).

Barry Lind
src/interfaces/jdbc/org/postgresql/Connection.java
src/interfaces/jdbc/org/postgresql/Driver.java.in
src/interfaces/jdbc/org/postgresql/ResultSet.java
src/interfaces/jdbc/org/postgresql/jdbc1/Connection.java
src/interfaces/jdbc/org/postgresql/jdbc1/PreparedStatement.java
src/interfaces/jdbc/org/postgresql/jdbc1/ResultSet.java
src/interfaces/jdbc/org/postgresql/jdbc2/Connection.java
src/interfaces/jdbc/org/postgresql/jdbc2/PreparedStatement.java
src/interfaces/jdbc/org/postgresql/jdbc2/ResultSet.java
src/interfaces/jdbc/org/postgresql/util/PGbytea.java [new file with mode: 0644]