OSDN Git Service

MIPS: RB532: Fix reregistering of serial console
authorWaldemar Brodkorb <wbx@openadk.org>
Thu, 3 Jul 2014 14:17:53 +0000 (16:17 +0200)
committerRalf Baechle <ralf@linux-mips.org>
Wed, 30 Jul 2014 11:27:51 +0000 (13:27 +0200)
commitf98fd44bebac6aa203eaf8a433d3a3ded374bae5
treeb3f62ca85d5da225f27db56e85fc37c6a06aa057
parent82242d28ff8bd2b3e0230190529c1ff333c766e1
MIPS: RB532: Fix reregistering of serial console

Runtime tested on Mikrotik RB532 board.
Thanks goes to Geert Uytterhoeven for the explanation of the problem.

"I'm afraid this is not gonna help. When the port is unregistered,
its type will be reset to PORT_UNKNOWN.
So before registering it again, its type must be set again the actual
serial driver, cfr. the change to of_serial.c."

Signed-off-by: Waldemar Brodkorb <wbx@openadk.org>
Reviewed-by: Florian Fainelli <florian@openwrt.org>
Cc: Linux MIPS Mailing List <linux-mips@linux-mips.org>
Cc: geert@linux-m68k.org
Cc: linux-kernel@vger.kernel.org
Patchwork: https://patchwork.linux-mips.org/patch/7241/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
arch/mips/rb532/devices.c