OSDN Git Service

DOCS: document API 19+ Alarm Manager API and behaviors
authorChristopher Tate <ctate@google.com>
Fri, 25 Oct 2013 20:59:44 +0000 (13:59 -0700)
committerChristopher Tate <ctate@google.com>
Fri, 25 Oct 2013 20:59:44 +0000 (13:59 -0700)
Bug 9941334

Change-Id: I65473bd62f7113c74ed6277d61db56c76441ff1b

core/java/android/app/AlarmManager.java

index 5c3a3e5..27b5a5a 100644 (file)
@@ -109,21 +109,19 @@ public class AlarmManager
     }
 
     /**
-     * TBW: discussion of fuzzy nature of alarms in KLP+.
-     *
      * <p>Schedule an alarm.  <b>Note: for timing operations (ticks, timeouts,
-     * etc) it is easier and much more efficient to use
-     * {@link android.os.Handler}.</b>  If there is already an alarm scheduled
-     * for the same IntentSender, it will first be canceled.
+     * etc) it is easier and much more efficient to use {@link android.os.Handler}.</b>
+     * If there is already an alarm scheduled for the same IntentSender, that previous
+     * alarm will first be canceled.
      *
-     * <p>If the time occurs in the past, the alarm will be triggered
+     * <p>If the stated trigger time is in the past, the alarm will be triggered
      * immediately.  If there is already an alarm for this Intent
      * scheduled (with the equality of two intents being defined by
      * {@link Intent#filterEquals}), then it will be removed and replaced by
      * this one.
      *
      * <p>
-     * The alarm is an intent broadcast that goes to a broadcast receiver that
+     * The alarm is an Intent broadcast that goes to a broadcast receiver that
      * you registered with {@link android.content.Context#registerReceiver}
      * or through the &lt;receiver&gt; tag in an AndroidManifest.xml file.
      *
@@ -133,9 +131,32 @@ public class AlarmManager
      * how many past alarm events have been accumulated into this intent
      * broadcast.  Recurring alarms that have gone undelivered because the
      * phone was asleep may have a count greater than one when delivered.  
-     *  
-     * @param type One of ELAPSED_REALTIME, ELAPSED_REALTIME_WAKEUP, RTC or
-     *             RTC_WAKEUP.
+     *
+     * <p>
+     * <b>Note:</b> Beginning in API 19, the trigger time passed to this method
+     * is treated as inexact: the alarm will not be delivered before this time, but
+     * may be deferred and delivered some time later.  The OS will use
+     * this policy in order to "batch" alarms together across the entire system,
+     * minimizing the number of times the device needs to "wake up" and minimizing
+     * battery use.  In general, alarms scheduled in the near future will not
+     * be deferred as long as alarms scheduled far in the future.
+     *
+     * <p>
+     * With the new batching policy, delivery ordering guarantees are not as
+     * strong as they were previously.  If the application sets multiple alarms,
+     * it is possible that these alarms' <i>actual</i> delivery ordering may not match
+     * the order of their <i>requested</i> delivery times.  If your application has
+     * strong ordering requirements there are other APIs that you can use to get
+     * the necessary behavior; see {@link #setWindow(int, long, long, PendingIntent)}
+     * and {@link #setExact(int, long, PendingIntent)}.
+     *
+     * <p>
+     * <b>Note:</b> Applications whose targetSdkVersion is before API 19 will
+     * continue to get the previous alarm behavior: all of their scheduled alarms
+     * will be treated as exact.
+     *
+     * @param type One of {@link #ELAPSED_REALTIME}, {@link #ELAPSED_REALTIME_WAKEUP},
+     *        {@link #RTC}, or {@link #RTC_WAKEUP}.
      * @param triggerAtMillis time in milliseconds that the alarm should go
      * off, using the appropriate clock (depending on the alarm type).
      * @param operation Action to perform when the alarm goes off;
@@ -165,10 +186,10 @@ public class AlarmManager
      * {@link android.os.Handler}.</b>  If there is already an alarm scheduled
      * for the same IntentSender, it will first be canceled.
      *
-     * <p>Like {@link #set}, except you can also
-     * supply a rate at which the alarm will repeat.  This alarm continues
-     * repeating until explicitly removed with {@link #cancel}.  If the time
-     * occurs in the past, the alarm will be triggered immediately, with an
+     * <p>Like {@link #set}, except you can also supply a period at which
+     * the alarm will automatically repeat.  This alarm continues
+     * repeating until explicitly removed with {@link #cancel}.  If the stated
+     * trigger time is in the past, the alarm will be triggered immediately, with an
      * alarm count depending on how far in the past the trigger time is relative
      * to the repeat interval.
      *
@@ -185,8 +206,15 @@ public class AlarmManager
      * between alarms, then the approach to take is to use one-time alarms, 
      * scheduling the next one yourself when handling each alarm delivery.
      *
-     * @param type One of ELAPSED_REALTIME, ELAPSED_REALTIME_WAKEUP}, RTC or
-     *             RTC_WAKEUP.
+     * <p>
+     * <b>Note:</b> as of API 19, all repeating alarms are inexact.  If your
+     * application needs precise delivery times then it must use one-time
+     * exact alarms, rescheduling each time as described above. Legacy applications
+     * whose targetSdkVersion is earlier than API 19 will continue to have all
+     * of their alarms, including repeating alarms, treated as exact.
+     *
+     * @param type One of {@link #ELAPSED_REALTIME}, {@link #ELAPSED_REALTIME_WAKEUP},
+     *        {@link #RTC}, or {@link #RTC_WAKEUP}.
      * @param triggerAtMillis time in milliseconds that the alarm should first
      * go off, using the appropriate clock (depending on the alarm type).
      * @param intervalMillis interval in milliseconds between subsequent repeats
@@ -214,18 +242,32 @@ public class AlarmManager
     }
 
     /**
-     * Schedule an alarm to be delivered within a given window of time.
+     * Schedule an alarm to be delivered within a given window of time.  This method
+     * is similar to {@link #set(int, long, PendingIntent)}, but allows the
+     * application to precisely control the degree to which its delivery might be
+     * adjusted by the OS. This method allows an application to take advantage of the
+     * battery optimizations that arise from delivery batching even when it has
+     * modest timeliness requirements for its alarms.
      *
-     * TBW: clean up these docs
+     * <p>
+     * This method can also be used to achieve strict ordering guarantees by ensuring
+     * that the windows requested for each alarm do not intersect.
      *
-     * @param type One of ELAPSED_REALTIME, ELAPSED_REALTIME_WAKEUP, RTC or
-     *        RTC_WAKEUP.
+     * <p>
+     * When precise delivery is not required, applications should use the standard
+     * {@link #set(int, long, PendingIntent)} method.  This will give the OS the most
+     * ability to minimize wakeups and battery use.  For alarms that must be delivered
+     * at precisely-specified times with no acceptable variation, applications can use
+     * {@link #setExact(int, long, PendingIntent)}.
+     *
+     * @param type One of {@link #ELAPSED_REALTIME}, {@link #ELAPSED_REALTIME_WAKEUP},
+     *        {@link #RTC}, or {@link #RTC_WAKEUP
      * @param windowStartMillis The earliest time, in milliseconds, that the alarm should
      *        be delivered, expressed in the appropriate clock's units (depending on the alarm
      *        type).
      * @param windowLengthMillis The length of the requested delivery window,
      *        in milliseconds.  The alarm will be delivered no later than this many
-     *        milliseconds after the windowStartMillis time.  Note that this parameter
+     *        milliseconds after {@code windowStartMillis}.  Note that this parameter
      *        is a <i>duration,</i> not the timestamp of the end of the window.
      * @param operation Action to perform when the alarm goes off;
      *        typically comes from {@link PendingIntent#getBroadcast
@@ -249,8 +291,38 @@ public class AlarmManager
     }
 
     /**
-     * TBW: new 'exact' alarm that must be delivered as nearly as possible
-     * to the precise time specified.
+     * Schedule an alarm to be delivered precisely at the stated time.
+     *
+     * <p>
+     * This method is like {@link #set(int, long, PendingIntent)}, but does not permit
+     * the OS to adjust the delivery time.  The alarm will be delivered as nearly as
+     * possible to the requested trigger time.
+     *
+     * <p>
+     * <b>Note:</b> only alarms for which there is a strong demand for exact-time
+     * delivery (such as an alarm clock ringing at the requested time) should be
+     * scheduled as exact.  Applications are strongly discouraged from using exact
+     * alarms unnecessarily as they reduce the OS's ability to minimize battery use.
+     *
+     * @param type One of {@link #ELAPSED_REALTIME}, {@link #ELAPSED_REALTIME_WAKEUP},
+     *        {@link #RTC}, or {@link #RTC_WAKEUP}.
+     * @param triggerAtMillis time in milliseconds that the alarm should go
+     *        off, using the appropriate clock (depending on the alarm type).
+     * @param operation Action to perform when the alarm goes off;
+     *        typically comes from {@link PendingIntent#getBroadcast
+     *        IntentSender.getBroadcast()}.
+     *
+     * @see #set
+     * @see #setRepeating
+     * @see #setWindow
+     * @see #cancel
+     * @see android.content.Context#sendBroadcast
+     * @see android.content.Context#registerReceiver
+     * @see android.content.Intent#filterEquals
+     * @see #ELAPSED_REALTIME
+     * @see #ELAPSED_REALTIME_WAKEUP
+     * @see #RTC
+     * @see #RTC_WAKEUP
      */
     public void setExact(int type, long triggerAtMillis, PendingIntent operation) {
         setImpl(type, triggerAtMillis, WINDOW_EXACT, 0, operation, null);
@@ -332,8 +404,8 @@ public class AlarmManager
      * may vary.  If your application demands very low jitter, use
      * {@link #setRepeating} instead.
      *
-     * @param type One of ELAPSED_REALTIME, ELAPSED_REALTIME_WAKEUP}, RTC or
-     *             RTC_WAKEUP.
+     * @param type One of {@link #ELAPSED_REALTIME}, {@link #ELAPSED_REALTIME_WAKEUP},
+     *        {@link #RTC}, or {@link #RTC_WAKEUP}.
      * @param triggerAtMillis time in milliseconds that the alarm should first
      * go off, using the appropriate clock (depending on the alarm type).  This
      * is inexact: the alarm will not fire before this time, but there may be a