OSDN Git Service

iotests: Make nbd-fault-injector flush
authorMax Reitz <mreitz@redhat.com>
Mon, 22 Oct 2018 13:52:59 +0000 (14:52 +0100)
committerEduardo Habkost <ehabkost@redhat.com>
Wed, 31 Oct 2018 00:11:52 +0000 (21:11 -0300)
When closing a connection, make the nbd-fault-injector flush the socket.
Without this, the output is a bit unreliable with Python 3.

Signed-off-by: Max Reitz <mreitz@redhat.com>
Reviewed-by: Eduardo Habkost <ehabkost@redhat.com>
Reviewed-by: Cleber Rosa <crosa@redhat.com>
Reviewed-by: Eric Blake <eblake@redhat.com>
Message-Id: <20181022135307.14398-2-mreitz@redhat.com>
Signed-off-by: Eduardo Habkost <ehabkost@redhat.com>
tests/qemu-iotests/083.out
tests/qemu-iotests/nbd-fault-injector.py

index be6079d..f9af8bb 100644 (file)
@@ -41,6 +41,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo
 
 === Check disconnect after neg2 ===
 
+Unable to read from socket: Connection reset by peer
 Connection closed
 read failed: Input/output error
 
@@ -54,6 +55,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo
 
 === Check disconnect before request ===
 
+Unable to read from socket: Connection reset by peer
 Connection closed
 read failed: Input/output error
 
@@ -116,6 +118,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/
 
 === Check disconnect after neg-classic ===
 
+Unable to read from socket: Connection reset by peer
 Connection closed
 read failed: Input/output error
 
@@ -161,6 +164,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock
 
 === Check disconnect after neg2 ===
 
+Unable to read from socket: Connection reset by peer
+Connection closed
 read failed: Input/output error
 
 === Check disconnect 8 neg2 ===
@@ -173,6 +178,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock
 
 === Check disconnect before request ===
 
+Unable to read from socket: Connection reset by peer
+Connection closed
 read failed: Input/output error
 
 === Check disconnect after request ===
@@ -234,6 +241,8 @@ can't open device nbd+unix:///?socket=TEST_DIR/nbd.sock
 
 === Check disconnect after neg-classic ===
 
+Unable to read from socket: Connection reset by peer
+Connection closed
 read failed: Input/output error
 
 *** done
index f9193c0..439a090 100755 (executable)
@@ -112,6 +112,7 @@ class FaultInjectionSocket(object):
             if rule.match(event, io):
                 if rule.when == 0 or bufsize is None:
                     print('Closing connection on rule match %s' % rule.name)
+                    self.sock.flush()
                     sys.exit(0)
                 if rule.when != -1:
                     return rule.when