iwlwifi: thermal: support new temperature measurement API
authorGil Adam <gil.adam@intel.com>
Wed, 30 Sep 2020 13:31:22 +0000 (16:31 +0300)
committerLuca Coelho <luciano.coelho@intel.com>
Thu, 1 Oct 2020 19:01:00 +0000 (22:01 +0300)
New API for temperature measurement (DTS_MEASUREMENT_TRIGGER)
involves getting an immediate response from FW, and not waiting
for a notification like in previous APIs. Support new API while
keeping backwards compatibility.

Signed-off-by: Gil Adam <gil.adam@intel.com>
Signed-off-by: Luca Coelho <luciano.coelho@intel.com>
Link: https://lore.kernel.org/r/iwlwifi.20200930161256.b4893554d8e7.Ia4d7f389d4ac3256fcfe3ce6144e924dd6dbf6eb@changeid
Signed-off-by: Luca Coelho <luciano.coelho@intel.com>
drivers/net/wireless/intel/iwlwifi/fw/api/phy.h
drivers/net/wireless/intel/iwlwifi/mvm/tt.c

index 8991ddf..0debca6 100644 (file)
@@ -8,7 +8,7 @@
  * Copyright(c) 2012 - 2014 Intel Corporation. All rights reserved.
  * Copyright(c) 2013 - 2015 Intel Mobile Communications GmbH
  * Copyright(c) 2016 - 2017 Intel Deutschland GmbH
- * Copyright(c) 2019 Intel Corporation
+ * Copyright(c) 2019 - 2020 Intel Corporation
  *
  * This program is free software; you can redistribute it and/or modify
  * it under the terms of version 2 of the GNU General Public License as
@@ -31,7 +31,7 @@
  * Copyright(c) 2012 - 2014 Intel Corporation. All rights reserved.
  * Copyright(c) 2013 - 2015 Intel Mobile Communications GmbH
  * Copyright(c) 2016 - 2017 Intel Deutschland GmbH
- * Copyright(c) 2019 Intel Corporation
+ * Copyright(c) 2019 - 2020 Intel Corporation
  * All rights reserved.
  *
  * Redistribution and use in source and binary forms, with or without
@@ -214,6 +214,15 @@ struct iwl_dts_measurement_notif_v2 {
 } __packed; /* TEMPERATURE_MEASUREMENT_TRIGGER_NTFY_S_VER_2 */
 
 /**
+ * struct iwl_dts_measurement_resp - measurements response
+ *
+ * @temp: the measured temperature
+ */
+struct iwl_dts_measurement_resp {
+       __le32 temp;
+} __packed; /* CMD_DTS_MEASUREMENT_RSP_API_S_VER_1 */
+
+/**
  * struct ct_kill_notif - CT-kill entry notification
  *
  * @temperature: the current temperature in celsius
index 0c95663..94e9b6d 100644 (file)
@@ -228,24 +228,67 @@ void iwl_mvm_ct_kill_notif(struct iwl_mvm *mvm, struct iwl_rx_cmd_buffer *rxb)
        iwl_mvm_enter_ctkill(mvm);
 }
 
-static int iwl_mvm_get_temp_cmd(struct iwl_mvm *mvm)
+/*
+ * send the DTS_MEASUREMENT_TRIGGER command with or without waiting for a
+ * response. If we get a response then the measurement is stored in 'temp'
+ */
+static int iwl_mvm_send_temp_cmd(struct iwl_mvm *mvm, bool response, s32 *temp)
 {
-       struct iwl_dts_measurement_cmd cmd = {
+       struct iwl_host_cmd cmd = {};
+       struct iwl_dts_measurement_cmd dts_cmd = {
                .flags = cpu_to_le32(DTS_TRIGGER_CMD_FLAGS_TEMP),
        };
-       struct iwl_ext_dts_measurement_cmd extcmd = {
+       struct iwl_ext_dts_measurement_cmd ext_cmd = {
                .control_mode = cpu_to_le32(DTS_DIRECT_WITHOUT_MEASURE),
        };
-       u32 cmdid;
+       struct iwl_dts_measurement_resp *resp;
+       void *cmd_ptr;
+       int ret;
+       u32 cmd_flags = 0;
+       u16 len;
+
+       /* Check which command format is used (regular/extended) */
+       if (fw_has_capa(&mvm->fw->ucode_capa,
+                       IWL_UCODE_TLV_CAPA_EXTENDED_DTS_MEASURE)) {
+               len = sizeof(ext_cmd);
+               cmd_ptr = &ext_cmd;
+       } else {
+               len = sizeof(dts_cmd);
+               cmd_ptr = &dts_cmd;
+       }
+       /* The command version where we get a response is zero length */
+       if (response) {
+               cmd_flags = CMD_WANT_SKB;
+               len = 0;
+       }
 
-       cmdid = iwl_cmd_id(CMD_DTS_MEASUREMENT_TRIGGER_WIDE,
-                          PHY_OPS_GROUP, 0);
+       cmd.id =  WIDE_ID(PHY_OPS_GROUP, CMD_DTS_MEASUREMENT_TRIGGER_WIDE);
+       cmd.len[0] = len;
+       cmd.flags = cmd_flags;
+       cmd.data[0] = cmd_ptr;
 
-       if (!fw_has_capa(&mvm->fw->ucode_capa,
-                        IWL_UCODE_TLV_CAPA_EXTENDED_DTS_MEASURE))
-               return iwl_mvm_send_cmd_pdu(mvm, cmdid, 0, sizeof(cmd), &cmd);
+       IWL_DEBUG_TEMP(mvm,
+                      "Sending temperature measurement command - %s response\n",
+                      response ? "with" : "without");
+       ret = iwl_mvm_send_cmd(mvm, &cmd);
 
-       return iwl_mvm_send_cmd_pdu(mvm, cmdid, 0, sizeof(extcmd), &extcmd);
+       if (ret) {
+               IWL_ERR(mvm,
+                       "Failed to send the temperature measurement command (err=%d)\n",
+                       ret);
+               return ret;
+       }
+
+       if (response) {
+               resp = (void *)cmd.resp_pkt->data;
+               *temp = le32_to_cpu(resp->temp);
+               IWL_DEBUG_TEMP(mvm,
+                              "Got temperature measurement response: temp=%d\n",
+                              *temp);
+               iwl_free_resp(&cmd);
+       }
+
+       return ret;
 }
 
 int iwl_mvm_get_temp(struct iwl_mvm *mvm, s32 *temp)
@@ -254,6 +297,18 @@ int iwl_mvm_get_temp(struct iwl_mvm *mvm, s32 *temp)
        static u16 temp_notif[] = { WIDE_ID(PHY_OPS_GROUP,
                                            DTS_MEASUREMENT_NOTIF_WIDE) };
        int ret;
+       u8 cmd_ver;
+
+       /*
+        * If command version is 1 we send the command and immediately get
+        * a response. For older versions we send the command and wait for a
+        * notification (no command TLV for previous versions).
+        */
+       cmd_ver = iwl_fw_lookup_cmd_ver(mvm->fw, PHY_OPS_GROUP,
+                                       CMD_DTS_MEASUREMENT_TRIGGER_WIDE,
+                                       IWL_FW_CMD_VER_UNKNOWN);
+       if (cmd_ver == 1)
+               return iwl_mvm_send_temp_cmd(mvm, true, temp);
 
        lockdep_assert_held(&mvm->mutex);
 
@@ -261,9 +316,8 @@ int iwl_mvm_get_temp(struct iwl_mvm *mvm, s32 *temp)
                                   temp_notif, ARRAY_SIZE(temp_notif),
                                   iwl_mvm_temp_notif_wait, temp);
 
-       ret = iwl_mvm_get_temp_cmd(mvm);
+       ret = iwl_mvm_send_temp_cmd(mvm, false, temp);
        if (ret) {
-               IWL_ERR(mvm, "Failed to get the temperature (err=%d)\n", ret);
                iwl_remove_notification(&mvm->notif_wait, &wait_temp_notif);
                return ret;
        }