OSDN Git Service

clk: shmobile: div6: Avoid changing divisor in .disable()
authorGeert Uytterhoeven <geert+renesas@glider.be>
Mon, 24 Nov 2014 14:57:59 +0000 (15:57 +0100)
committerGeert Uytterhoeven <geert+renesas@glider.be>
Thu, 8 Jan 2015 15:13:19 +0000 (16:13 +0100)
While DIV6 clocks require the divisor field to be non-zero when stopping
the clock, some clocks (e.g. ZB on sh73a0) fail to be re-enabled later
if the divisor field is changed when stopping the clock.
The reason for this is unknown.

To fix this, do not touch the divisor field if it's already non-zero.

On kzm9g, the smsc911x Ethernet controller is connected to the sh73a0
Bus State Controller, which is clocked by the ZB clock. Without this
fix, if the ZB clock is disabled during system suspend, and re-enabled
during resume, the kernel locks up when the smsc911x driver tries to
access the Ethernet registers.

Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Acked-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
drivers/clk/shmobile/clk-div6.c

index 639241e..efbaf6c 100644 (file)
@@ -54,12 +54,19 @@ static int cpg_div6_clock_enable(struct clk_hw *hw)
 static void cpg_div6_clock_disable(struct clk_hw *hw)
 {
        struct div6_clock *clock = to_div6_clock(hw);
+       u32 val;
 
-       /* DIV6 clocks require the divisor field to be non-zero when stopping
-        * the clock.
+       val = clk_readl(clock->reg);
+       val |= CPG_DIV6_CKSTP;
+       /*
+        * DIV6 clocks require the divisor field to be non-zero when stopping
+        * the clock. However, some clocks (e.g. ZB on sh73a0) fail to be
+        * re-enabled later if the divisor field is changed when stopping the
+        * clock
         */
-       clk_writel(clk_readl(clock->reg) | CPG_DIV6_CKSTP | CPG_DIV6_DIV_MASK,
-                  clock->reg);
+       if (!(val & CPG_DIV6_DIV_MASK))
+               val |= CPG_DIV6_DIV_MASK;
+       clk_writel(val, clock->reg);
 }
 
 static int cpg_div6_clock_is_enabled(struct clk_hw *hw)