OSDN Git Service

ARM: dts: msm: Update APC0/1 CPR voltage margins for sdm660
authorTirupathi Reddy <tirupath@codeaurora.org>
Mon, 27 Feb 2017 06:49:07 +0000 (12:19 +0530)
committerTirupathi Reddy <tirupath@codeaurora.org>
Mon, 27 Feb 2017 06:49:07 +0000 (12:19 +0530)
Update APC0/1 CPR open-loop and closed-loop static voltage
margins for sdm660 as per new voltage characterization results.

Change-Id: If09add7cadbe36fa6455a86c372668891a3822dd
Signed-off-by: Tirupathi Reddy <tirupath@codeaurora.org>
arch/arm/boot/dts/qcom/sdm660-regulator.dtsi

index 47db57b..462a76e 100644 (file)
                                qcom,cpr-corner-fmax-map = <2 3 4 5 8>;
 
                                qcom,cpr-voltage-ceiling =
-                                       <724000  724000  724000  788000  868000
-                                        924000  988000 1068000>;
+                                       < 724000  724000  724000  788000  868000
+                                        1068000 1068000 1068000>;
 
                                qcom,cpr-voltage-floor =
                                        <588000  588000  596000  652000  712000
                                         4370 4780>;
 
                                qcom,cpr-open-loop-voltage-fuse-adjustment =
-                                       <13000 31000 27000 37000 21000>;
+                                       < (-4000)  4000  7000  19000 (-8000)>;
 
                                qcom,cpr-closed-loop-voltage-fuse-adjustment =
-                                       <0     0     0     0      8000>;
+                                       <(-32000) (-30000) (-29000) (-23000)
+                                       (-21000)>;
 
                                qcom,cpr-floor-to-ceiling-max-range =
-                                       <32000  32000  32000  40000  40000
+                                       <32000  32000  32000  40000  44000
                                         40000  40000  40000>;
                        };
                };
 
                                qcom,cpr-voltage-ceiling =
                                        <724000  724000  788000  868000
-                                        924000  988000 1068000>;
+                                        988000  988000 1068000>;
 
                                qcom,cpr-voltage-floor =
                                        <588000  596000  652000  712000
                                         2620 2280>;
 
                                qcom,cpr-open-loop-voltage-fuse-adjustment =
-                                       <31000 39000 53000 40000 29000>;
+                                       <16000 27000 39000 39000 20000>;
 
                                qcom,cpr-closed-loop-voltage-fuse-adjustment =
-                                       <0      3000 19000 23000 28000>;
+                                       <(-22000) (-9000) (-7000) (-2000)
+                                          11000>;
 
                                qcom,cpr-floor-to-ceiling-max-range =
                                        <40000  40000  40000  40000
-                                        40000  40000  40000>;
+                                        66000  66000  40000>;
                        };
                };
        };