OSDN Git Service

(hppa_fix_adjustable): Don't reduce certain symbols to section syms.
authorAlan Modra <amodra@bigpond.net.au>
Sat, 15 Jul 2000 12:57:14 +0000 (12:57 +0000)
committerAlan Modra <amodra@bigpond.net.au>
Sat, 15 Jul 2000 12:57:14 +0000 (12:57 +0000)
gas/ChangeLog
gas/config/tc-hppa.c

index 36bad54..41113b8 100644 (file)
@@ -1,3 +1,10 @@
+2000-07-15  Alan Modra  <alan@linuxcare.com.au>
+
+       * config/tc-hppa.c (hppa_fix_adjustable): Use the same checks for
+       ELF as are used for SOM (except the 32-bit reloc one) to decide
+       whether a symbol can be reduced to a section symbol.  Expand on
+       the comment for symbols involved in LR% and RR% expressions.
+
 2000-07-14  Nick Clifton  <nickc@cygnus.com>
 
        * config/tc-mips.c (mips_disable_float_construction): New
index 313b229..67eb611 100644 (file)
@@ -4431,7 +4431,7 @@ md_apply_fix (fixP, valp)
     }
 #endif
 
-  insn = bfd_get_32 (stdoutput, (unsigned char *)buf);
+  insn = bfd_get_32 (stdoutput, (unsigned char *) buf);
   /* There should have been an HPPA specific fixup associated
      with the GAS fixup.  */
   if (hppa_fixP)
@@ -8342,6 +8342,7 @@ hppa_fix_adjustable (fixp)
   /* Reject reductions of symbols in 32bit relocs.  */
   if (fixp->fx_r_type == R_HPPA && hppa_fix->fx_r_format == 32)
     return 0;
+#endif
 
   /* Reject reductions of symbols in sym1-sym2 expressions when
      the fixup will occur in a CODE subspace.
@@ -8359,12 +8360,38 @@ hppa_fix_adjustable (fixp)
     }
 
   /* We can't adjust any relocs that use LR% and RR% field selectors.
-     That confuses the HP linker.  */
+
+     If a symbol is reduced to a section symbol, the assembler will
+     adjust the addend unless the symbol happens to reside right at
+     the start of the section.  Additionally, the linker has no choice
+     but to manipulate the addends when coalescing input sections for
+     "ld -r".  Since an LR% field selector is defined to round the
+     addend, we can't change the addend without risking that a LR% and
+     it's corresponding (possible multiple) RR% field will no longer
+     sum to the right value.
+
+     eg. Suppose we have
+     .         ldil    LR%foo+0,%r21
+     .         ldw     RR%foo+0(%r21),%r26
+     .         ldw     RR%foo+10(%r21),%r25
+
+     If foo is at address 4090 (decimal) in section `sect', then after
+     reducing to the section symbol, we get
+     .                 LR%sect+4090 == L%sect+0
+     .                 RR%sect+4090 == R%sect+4090
+     .                 RR%sect+4100 == R%sect-4092 (4100 - 8192)
+     and the last address loses.
+
+     Obviously, in cases where the LR% expression is identical to the
+     RR% one we will never have a problem, but is so happens that gcc
+     rounds addends involved in LR% field selectors to work around a
+     HP linker bug.  ie. We often have addresses like the last case
+     above where the LR% expression is offset from the RR% one.  */
+
   if (hppa_fix->fx_r_field == e_lrsel
       || hppa_fix->fx_r_field == e_rrsel
       || hppa_fix->fx_r_field == e_nlrsel)
     return 0;
-#endif
 
   /* Reject reductions of symbols in DLT relative relocs,
      relocations with plabels.  */