OSDN Git Service

net: hns3: change default tc state to close
authorJian Shen <shenjian15@huawei.com>
Thu, 20 Dec 2018 03:51:59 +0000 (11:51 +0800)
committerDavid S. Miller <davem@davemloft.net>
Thu, 20 Dec 2018 07:47:58 +0000 (23:47 -0800)
In original codes, default tc value is set to the max tc. It's more
reasonable to close tc by changing default tc value to 1. Users can
enable it with lldp tool when they want to use tc.

Signed-off-by: Jian Shen <shenjian15@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_main.c

index a12cb14..0b04d04 100644 (file)
@@ -960,7 +960,7 @@ static int hclge_configure(struct hclge_dev *hdev)
                hdev->pfc_max = hdev->tc_max;
        }
 
-       hdev->tm_info.num_tc = hdev->tc_max;
+       hdev->tm_info.num_tc = 1;
 
        /* Currently not support uncontiuous tc */
        for (i = 0; i < hdev->tm_info.num_tc; i++)