OSDN Git Service

spapr: drop useless dynamic sysbus device sanity check
authorGreg Kurz <groug@kaod.org>
Wed, 11 Apr 2018 15:01:20 +0000 (17:01 +0200)
committerDavid Gibson <david@gibson.dropbear.id.au>
Fri, 27 Apr 2018 08:05:22 +0000 (18:05 +1000)
Since commit 7da79a167aa11, the machine class init function registers
dynamic sysbus device types it supports. Passing an unsupported device
type on the command line causes QEMU to exit with an error message
just after machine init.

It is hence not needed to do the same sanity check at machine reset.

Signed-off-by: Greg Kurz <groug@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
hw/ppc/spapr.c

index fc86ba6..d35a88c 100644 (file)
@@ -1440,21 +1440,6 @@ void spapr_setup_hpt_and_vrma(sPAPRMachineState *spapr)
     }
 }
 
-static void find_unknown_sysbus_device(SysBusDevice *sbdev, void *opaque)
-{
-    bool matched = false;
-
-    if (object_dynamic_cast(OBJECT(sbdev), TYPE_SPAPR_PCI_HOST_BRIDGE)) {
-        matched = true;
-    }
-
-    if (!matched) {
-        error_report("Device %s is not supported by this machine yet.",
-                     qdev_fw_name(DEVICE(sbdev)));
-        exit(1);
-    }
-}
-
 static int spapr_reset_drcs(Object *child, void *opaque)
 {
     sPAPRDRConnector *drc =
@@ -1478,9 +1463,6 @@ static void spapr_machine_reset(void)
     void *fdt;
     int rc;
 
-    /* Check for unknown sysbus devices */
-    foreach_dynamic_sysbus_device(find_unknown_sysbus_device, NULL);
-
     spapr_caps_reset(spapr);
 
     first_ppc_cpu = POWERPC_CPU(first_cpu);