ATAPI: STARTSTOPUNIT only eject/load media if powercondition is 0
authorRonnie Sahlberg <ronniesahlberg@gmail.com>
Tue, 31 Jul 2012 01:28:26 +0000 (11:28 +1000)
committerKevin Wolf <kwolf@redhat.com>
Wed, 12 Sep 2012 13:50:09 +0000 (15:50 +0200)
The START STOP UNIT command will only eject/load media if
power condition is zero.

If power condition is !0 then LOEJ and START will be ignored.

From MMC (sbc contains similar wordings too)
  The Power Conditions field requests the block device to be placed
  in the power condition defined in
  Table 558. If this field has a value other than 0h then the Start
  and LoEj bits shall be ignored.

Signed-off-by: Ronnie Sahlberg <ronniesahlberg@gmail.com>
Signed-off-by: Kevin Wolf <kwolf@redhat.com>
hw/ide/atapi.c

index f7f714c..685cbaa 100644 (file)
@@ -875,6 +875,12 @@ static void cmd_start_stop_unit(IDEState *s, uint8_t* buf)
     int sense;
     bool start = buf[4] & 1;
     bool loej = buf[4] & 2;     /* load on start, eject on !start */
+    int pwrcnd = buf[4] & 0xf0;
+
+    if (pwrcnd) {
+        /* eject/load only happens for power condition == 0 */
+        return;
+    }
 
     if (loej) {
         if (!start && !s->tray_open && s->tray_locked) {