} else {
/* We expect errors as the qp is drained during shutdown */
if (rds_conn_up(conn) || rds_conn_connecting(conn))
- rds_ib_conn_error(conn, "recv completion on <%pI6c,%pI6c, %d> had status %u (%s), disconnecting and reconnecting\n",
+ rds_ib_conn_error(conn, "recv completion on <%pI6c,%pI6c, %d> had status %u (%s), vendor err 0x%x, disconnecting and reconnecting\n",
&conn->c_laddr, &conn->c_faddr,
conn->c_tos, wc->status,
- ib_wc_status_msg(wc->status));
+ ib_wc_status_msg(wc->status),
+ wc->vendor_err);
}
/* rds_ib_process_recv() doesn't always consume the frag, and
/* We expect errors as the qp is drained during shutdown */
if (wc->status != IB_WC_SUCCESS && rds_conn_up(conn)) {
- rds_ib_conn_error(conn, "send completion on <%pI6c,%pI6c,%d> had status %u (%s), disconnecting and reconnecting\n",
+ rds_ib_conn_error(conn, "send completion on <%pI6c,%pI6c,%d> had status %u (%s), vendor err 0x%x, disconnecting and reconnecting\n",
&conn->c_laddr, &conn->c_faddr,
conn->c_tos, wc->status,
- ib_wc_status_msg(wc->status));
+ ib_wc_status_msg(wc->status), wc->vendor_err);
}
}