platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table
authorJan Kiszka <jan.kiszka@siemens.com>
Wed, 4 Sep 2019 06:42:30 +0000 (08:42 +0200)
committerAndy Shevchenko <andriy.shevchenko@linux.intel.com>
Sat, 7 Sep 2019 18:16:09 +0000 (21:16 +0300)
commitad0d315b4d4e7138f43acf03308192ec00e9614d
tree0393bc838290e7f081cfe8f525ca6ebca4dc793b
parent0b43e41e93815ecd9616759cf5d64d3a7be8e6fb
platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table

The SIMATIC IPC227E uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this device
to the critical systems list.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
drivers/platform/x86/pmc_atom.c