OSDN Git Service

platform/x86: pmc_atom: Add Siemens SIMATIC IPC277E to critclk_systems DMI table
authorSrikanth Krishnakar <skrishnakar@gmail.com>
Fri, 20 Sep 2019 09:31:56 +0000 (15:01 +0530)
committerAndy Shevchenko <andriy.shevchenko@linux.intel.com>
Fri, 20 Sep 2019 14:56:24 +0000 (17:56 +0300)
commitf110d252ae7985def3cd0fd8b03979180a8633a0
tree1c8a7cdfebdafcff75cedb489347fe93f6d0efc1
parentb3abfd778bf1dbdd96f70bd7d00671d027f67c62
platform/x86: pmc_atom: Add Siemens SIMATIC IPC277E to critclk_systems DMI table

The SIMATIC IPC277E uses the PMC clock for on-board components
and gets stuck during boot if the clock is disabled. Therefore,
add this device to the critical systems list.

Tested on SIMATIC IPC277E.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Reviewed-by: Jan Kiszka <jan.kiszka@siemens.com>
Cc: Cedric Hombourger <Cedric_Hombourger@mentor.com>
Signed-off-by: Srikanth Krishnakar <Srikanth_Krishnakar@mentor.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
drivers/platform/x86/pmc_atom.c