From 075167ed71b7bd9fdeaa5c2f69179471d17e3712 Mon Sep 17 00:00:00 2001 From: Andre Przywara Date: Thu, 21 May 2015 17:26:19 +0100 Subject: [PATCH] drivers: PL011: replace UART_MIS reading with _RIS & _IMSC The PL011 register UART_MIS is actually a bitwise AND of the UART_RIS and the UART_MISC register. Since the SBSA UART does not include the _MIS register, use the two separate registers to get the same behaviour. Since we are inside the spinlock and we read the _IMSC register only once, there should be no race issue. Signed-off-by: Andre Przywara Tested-by: Mark Langsdorf Tested-by: Naresh Bhat Signed-off-by: Greg Kroah-Hartman --- drivers/tty/serial/amba-pl011.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-) diff --git a/drivers/tty/serial/amba-pl011.c b/drivers/tty/serial/amba-pl011.c index 38d2245d7485..b66636bf06a0 100644 --- a/drivers/tty/serial/amba-pl011.c +++ b/drivers/tty/serial/amba-pl011.c @@ -1322,11 +1322,13 @@ static irqreturn_t pl011_int(int irq, void *dev_id) struct uart_amba_port *uap = dev_id; unsigned long flags; unsigned int status, pass_counter = AMBA_ISR_PASS_LIMIT; + u16 imsc; int handled = 0; unsigned int dummy_read; spin_lock_irqsave(&uap->port.lock, flags); - status = readw(uap->port.membase + UART011_MIS); + imsc = readw(uap->port.membase + UART011_IMSC); + status = readw(uap->port.membase + UART011_RIS) & imsc; if (status) { do { if (uap->vendor->cts_event_workaround) { @@ -1361,7 +1363,7 @@ static irqreturn_t pl011_int(int irq, void *dev_id) if (pass_counter-- == 0) break; - status = readw(uap->port.membase + UART011_MIS); + status = readw(uap->port.membase + UART011_RIS) & imsc; } while (status != 0); handled = 1; } -- 2.11.0