From 2fa9b361e500a0e092a9525afbd6a3a363ffa5f0 Mon Sep 17 00:00:00 2001 From: Yixun Lan Date: Fri, 19 Jan 2018 10:09:26 +0800 Subject: [PATCH] clk: meson: axg: fix the od shift of the sys_pll According to the datasheet, the od shift of sys_pll is actually 16. Fixes: 78b4af312f91 ('clk: meson-axg: add clock controller drivers') Signed-off-by: Yixun Lan [fixed commit message] Signed-off-by: Jerome Brunet --- drivers/clk/meson/axg.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/clk/meson/axg.c b/drivers/clk/meson/axg.c index a1ac0ff67e5f..455d4d8962bb 100644 --- a/drivers/clk/meson/axg.c +++ b/drivers/clk/meson/axg.c @@ -64,7 +64,7 @@ static struct meson_clk_pll axg_sys_pll = { }, .od = { .reg_off = HHI_SYS_PLL_CNTL, - .shift = 10, + .shift = 16, .width = 2, }, .lock = &meson_clk_lock, -- 2.11.0