OSDN Git Service

hwmon: (smsc47m192) Fix temperature limit and vrm write operations
authorGuenter Roeck <linux@roeck-us.net>
Fri, 18 Jul 2014 14:31:18 +0000 (07:31 -0700)
committerGuenter Roeck <linux@roeck-us.net>
Thu, 24 Jul 2014 13:25:25 +0000 (06:25 -0700)
commit043572d5444116b9d9ad8ae763cf069e7accbc30
treefdd8dc8c970e8d401a89f51d4594267896d548d2
parent9a3c4145af32125c5ee39c0272662b47307a8323
hwmon: (smsc47m192) Fix temperature limit and vrm write operations

Temperature limit clamps are applied after converting the temperature
from milli-degrees C to degrees C, so either the clamp limit needs
to be specified in degrees C, not milli-degrees C, or clamping must
happen before converting to degrees C. Use the latter method to avoid
overflows.

vrm is an u8, so the written value needs to be limited to [0, 255].

Cc: Axel Lin <axel.lin@ingics.com>
Cc: stable@vger.kernel.org
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Jean Delvare <jdelvare@suse.de>
drivers/hwmon/smsc47m192.c