OSDN Git Service

rtc: s35390a: implement reset routine as suggested by the reference
authorUwe Kleine-König <uwe@kleine-koenig.org>
Sat, 2 Jul 2016 15:28:09 +0000 (17:28 +0200)
committerAlexandre Belloni <alexandre.belloni@free-electrons.com>
Mon, 11 Jul 2016 21:22:34 +0000 (23:22 +0200)
commit8e6583f1b5d1f5f129b873f1428b7e414263d847
treef5a155754891e57d25d4d8c2e5890a67af3dd252
parentf87e904ddd8f0ef120e46045b0addeb1cc88354e
rtc: s35390a: implement reset routine as suggested by the reference

There were two deviations from the reference manual: you have to wait
half a second when POC is active and you might have to repeat
initialization when POC or BLD are still set after the sequence.

Note however that as POC and BLD are cleared by read the driver might
not be able to detect that a reset is necessary. I don't have a good
idea how to fix this.

Additionally report the value read from STATUS1 to the caller. This
prepares the next patch.

Signed-off-by: Uwe Kleine-König <uwe@kleine-koenig.org>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
drivers/rtc/rtc-s35390a.c