OSDN Git Service

riscv: Fix SiFive E CLINT clock frequency
authorRomán Cárdenas <rcardenas.rod@gmail.com>
Fri, 17 Nov 2023 08:28:42 +0000 (09:28 +0100)
committerAlistair Francis <alistair.francis@wdc.com>
Wed, 22 Nov 2023 03:57:19 +0000 (13:57 +1000)
commita7472560ca5f7a61ef3a46b52118f680de81058c
treefac551ebc2b329e719645275a1a34790460e08a1
parent9bbf03275e1f02044a473634929724acb6b8eb32
riscv: Fix SiFive E CLINT clock frequency

If you check the manual of SiFive E310 (https://cdn.sparkfun.com/assets/7/f/0/2/7/fe310-g002-manual-v19p05.pdf),
you can see in Figure 1 that the CLINT is connected to the real time clock, which also feeds the AON peripheral (they share the same clock).
In page 43, the docs also say that the timer registers of the CLINT count ticks from the rtcclk.

I am currently playing with bare metal applications both in QEMU and a physical SiFive E310 board and
I confirm that the CLINT clock in the physical board runs at 32.768 kHz.
In QEMU, the same app produces a completely different outcome, as sometimes a new CLINT interrupt is triggered before finishing other tasks.

Resolves: https://gitlab.com/qemu-project/qemu/-/issues/1978

Signed-off-by: Rom\ufffd\ufffdn C\ufffd\ufffdrdenas <rcardenas.rod@gmail.com>
Reviewed-by: Alistair Francis <alistair.francis@wdc.com>
Reviewed-by: Daniel Henrique Barboza <dbarboza@ventanamicro.com>
Message-ID: <20231117082840.55705-1-rcardenas.rod@gmail.com>
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
hw/riscv/sifive_e.c